Cold Plunge Family with Short and Long Tank Options
The CT-12 cold plunge is a rounded red-cedar cold plunge family with two tank lengths with 304 stainless-steel liner with red-cedar exterior. Working overall dimensions: 1300 × 900 × 700 mm (CT-12-01) or 1600 × 900 × 700 mm (CT-12-02). Working internal dimensions: 1200 × 800 × 600 mm (CT-12-01) or 1500 × 800 × 600 mm (CT-12-02).…
Compare the brochure-defined short and long tank dimensions; final equipment and standard supply are confirmed in the RFQ.
- Capacity
- Usable volume to confirm
- Dimensions
- Tank 1200 × 800 × 600 mm; external 1300 × 900 × 700 mm
- Material
- 304 stainless-steel liner with red-cedar exterior
- Configuration
- Short CT-12 layout with cover and step shown
Confirm the final drawing, equipment and standard supply.
- Rounded red-cedar cold plunge family with two tank lengths
- Working size: 1300 × 900 × 700 mm (CT-12-01) or 1600 × 900 × 700 mm (CT-12-02)
- Material: 304 stainless-steel liner with red-cedar exterior
- Gallery images are family references; only configurations with an assigned image have model-specific imagery.
Confirm model, site, utilities, equipment, included items, options, destination, quantity and target timing.
Cold Plunge Family with Short and Long Tank Options
The CT-12 cold plunge gives wholesale, hospitality and project buyers a clear reference for the rounded red-cedar cold plunge family with two tank lengths. The photographed complete product establishes the visible form; the quotation confirms the selected materials, system, accessories and destination requirements.

What buyers can evaluate from this model.
Start with the complete product form, then verify the selected materials, dimensions, equipment and site interfaces.

Complete CT-12 cold plunge product view
The lead image shows the complete tub before closer construction, connection or application views.
Defined material and dimension starting point
The draft separates working comparison dimensions from the final approved drawing and itemized order specification.

RFQ-ready project configuration
Buyers can compare finishes, equipment and OEM needs while keeping unconfirmed items out of the standard supply.
Compare sizes, materials and configuration choices.
Use the working dimensions for comparison and the approved drawing and technical file for the order.
| Model | Capacity | Recorded dimensions / source status | Material | Heating / configuration |
|---|---|---|---|---|
| CT-12-01 | Usable volume to confirm | Tank 1200 × 800 × 600 mm; external 1300 × 900 × 700 mm | 304 stainless-steel liner with red-cedar exterior | Short CT-12 layout with cover and step shownConfirm the final drawing, equipment and standard supply. |
| CT-12-02 | Usable volume to confirm | Tank 1500 × 800 × 600 mm; external 1600 × 900 × 700 mm | 304 stainless-steel liner; red or blue exterior options shown | Long CT-12 layoutNo CT-12-02-specific image is assigned yet. The gallery remains a CT-12 family reference and does not represent the long option’s exact appearance. |
| Family | CT-12 Family |
|---|---|
| SKU | CT-12 |
| Model | CT-12 |
| Product Type | Rounded red-cedar cold plunge family with two tank lengths |
| Working Overall Dimensions | 1300 × 900 × 700 mm (CT-12-01) or 1600 × 900 × 700 mm (CT-12-02) |
| Working Internal Dimensions | 1200 × 800 × 600 mm (CT-12-01) or 1500 × 800 × 600 mm (CT-12-02) |
| Material Configuration | 304 stainless-steel liner with red-cedar exterior |
| System Configuration | External water-temperature equipment and connections to be selected |
| Available Choices | CT-12-01 short · CT-12-02 long |
The current product record provides two clear length configurations. Confirm usable volume, final connection positions and the approved drawing for the selected option.
Inspect the construction and user touchpoints.
Use the gallery to review visible construction and interfaces. Hidden functions, ratings and inclusions are confirmed in the model-specific technical file.

Overall product form
Review the complete vessel, exterior enclosure, entry arrangement and equipment zone visible in the gallery.

Vessel and exterior construction
Confirm the selected material, finish, thickness and fabrication details against the approved production specification.
Connections and service access
Use the final interface drawing to plan water, drainage, power, ventilation and maintenance clearance.
Confirm the site and utilities before ordering.
Confirm delivery access, finished base, water, drainage, electrical supply, ventilation and service responsibilities before ordering.
Prepare the site
Provide destination, site and access dimensions, finished base conditions, utilities, ambient conditions, expected use and preferred configuration.
Install & commission
Installation and commissioning must follow the approved drawing and manual for the exact configuration and applicable local requirements.
Operate & maintain
Operate, clean and inspect the final product under its approved manual and site sanitation plan. Keep connections, ventilation and service areas accessible.
Pre-order requirement check
Evaluate where this product may fit.
Application fit depends on the approved configuration, site, expected use, supervision and maintenance responsibilities.

CT-12-01 short-size reference
Complete product reference for the short CT-12 configuration.

Tank and cover review
The complete product view supports review of the vessel, exterior, access arrangement and equipment relationship.

Entry and exterior review
Additional same-model view for entry, exterior and equipment planning; it does not represent the unpictured CT-12-02 long option.
Turn the selected model into a quotation-ready brief.
After the base model and technical configuration are fixed, Bropool can review finish, branding, controls, accessories, documents and packing for the project.
Items to review with Bropool
- Exterior and finish reviewConfirm material, finish sample, trim and visual treatment for the selected model.
- Branding and control presentationReview logo placement and interface presentation after the technical configuration is approved.
- Documents and packingConfirm destination documents, labeling, manuals and packing requirements for the exact order.
No universal option, minimum quantity, surcharge, lead time, certificate or performance result is promised before model-specific review.
A clear path from configuration to delivery.
Packing, documents, handling and delivery are confirmed after the exact model and configuration are approved.
01. Confirm
Confirm model, destination, quantity, options, site constraints and buyer responsibilities.
02. Document
Review the final drawing, specification, manual, packing list and applicable market documents.
03. Protect
Confirm model-specific packing method, packed dimensions, gross weight and handling points.
04. Deliver
Confirm shipping, unloading and delivery terms for the exact destination.
Built for model selection, configuration review and RFQ.
Bropool maintains this page as the manufacturing and project-supply reference for CT-12 Family. It supports comparison and quotation preparation; the approved quotation and technical file control the final order.
Bropool
Product identity, supplied photography and quotation-stage information are maintained at company level by Bropool.
Model records + supplied media
Visible claims are based on the current product record and supplied photography. Dimensions, electrical data, inclusions and market requirements remain subject to approved project documents.
Page checked September 14, 2026
Options, installation conditions, documents, branding and delivery scope are confirmed against the selected model and destination market.
Questions to settle before quotation.
Common buyer questions are answered while final technical and commercial scope remains model-specific.
What dimensions are available for the CT-12 cold plunge?
Working overall dimensions are 1300 × 900 × 700 mm (CT-12-01) or 1600 × 900 × 700 mm (CT-12-02); working internal dimensions are 1200 × 800 × 600 mm (CT-12-01) or 1500 × 800 × 600 mm (CT-12-02). Confirm the final axes and production drawing before order.
What materials are specified for this model?
304 stainless-steel liner with red-cedar exterior. Confirm finish samples, construction details and any model-specific substitutions in the quotation.
Is the temperature-control equipment included?
Do not assume inclusion. External water-temperature equipment and connections to be selected. The formal quotation must itemize the equipment, controls, filtration, connections and accessories.
Can Bropool review an OEM or private-label configuration?
Yes. Send the base model, finish, branding, quantity, destination and document requirements for a configuration review. Availability and scope are confirmed for the specific project.
What site information should a buyer provide?
Provide the access route, finished base, water and drainage plan, available electrical supply, ambient conditions, service clearances and expected use.
What should the RFQ include?
Send the model, destination, quantity, target timing, site details, preferred finish, equipment requirements and any branding, document or packing requests.